ÇѱÛÁ¦¸ñ(Korean Title) ½ºÅ×·¹¿À ±â¹Ý °¨¸¶¼±¿ø ŽÁö ¹× °¡½ÃÈ­¿¡ °üÇÑ ¿¬±¸
¿µ¹®Á¦¸ñ(English Title) Study of the Radioactive Source Detection and the Visualization with the Stereo Radiation Detector
ÀúÀÚ(Author) ¹Ú°­Åà  À̳²È£   Â÷ÇÑÁÖ   Gang-teak Park   Nam-ho Lee   Han-ju Cha  
¿ø¹®¼ö·Ïó(Citation) VOL 19 NO. 02 PP. 1100 ~ 1102 (2015. 10)
Çѱ۳»¿ë
(Korean Abstract)
º» ³í¹®¿¡¼­´Â ½ºÅ×·¹¿À ±â¹Ý °¨¸¶¼±¿ø ŽÁöÀåÄ¡¸¦ ÅëÇØ °¨¸¶¼±¿øÀ» Æ÷ÇÔÇÏ´Â °ø°£À» ·¡½ºÅÍ ½ºÄµ¹æ½ÄÀ¸·Î ½ºÄµÇÏ¿© °¡½Ã±¤¿µ»ó°ú °¨¸¶¼±¿µ»óÀ» ȹµæÇÏ°í, ½ºÅ×·¹¿À °¨¸¶¼± ŽÁöÀåÄ¡·ÎºÎÅÍ ¼±¿ø±îÁöÀÇ °Å¸®¿Í ¹æÇâ¿¡ ´ëÇÑ 3Â÷¿ø Á¤º¸ ȹµæ ¹× °¡½ÃÈ­¸¦ ¼öÇàÇÏ¿´´Ù. ŽÁöÀåÄ¡ÀÇ ±¸¼ºÀº °¨¸¶¼±¿ø ŽÁö¸¦ À§ÇÑ ¹æ»ç¼± °ËÃâºÎ, ¼±¿øŽÁö¸¦ À§ÇØ ·¡½ºÅͽºÄµ¹æ½ÄÀÇ ½ºÄµÀ» À§ÇÑ ÆÒÆ¿Æ® ±×¸®°í °¡½Ã±¤¿µ»óÀ» À§ÇÑ CCD Ä«¸Þ¶ó·Î ÀÌ·ç¾îÁø´Ù. ¼±¿ø¿¡ ´ëÇÑ °ø°£ºÐÆ÷¸¦ ÃøÁ¤Çϱâ À§ÇØ ½ºÅ×·¹¿À ±¸Á¶ÀÇ ÀåÄ¡¸¦ ±¸ÇöÇÏ¿´À¸¸ç ½ºÅ×·¹¿À ¿µ»óȹµæÀ» À§ÇØ CCD Ä«¸Þ¶ó¿Í °¨¸¶¼± ŽÁöÀåÄ¡´Â °¢°¢ 2´ë·Î ±¸¼ºÇÏ¿´´Ù. ŽÁö¼±¿ø¿¡ ´ëÇÑ ºÐÆ÷¸¦ ³ªÅ¸³»±â À§ÇØ °¨¸¶¼± ŽÁö ÀåÄ¡¿Í °¡½Ã±¤ Ä«¸Þ¶ó¿¡ ´ëÇÑ º¸Á¤À» ¼öÇàÇÏ¿´°í, °¢°¢ÀÇ Ä«¸Þ¶ó¿¡ ´ëÇÑ ½ºÅ×·¹¿À º¸Á¤À» ¼öÇàÇÑ ÈÄ °¡½Ã±¤¿µ»ó°ú °¨¸¶¼±¿µ»ó ÁßøÀ» ÅëÇØ °¨¸¶¼±¿ø¿¡ ´ëÇÑ ºÐÆ÷¸¦ ³ªÅ¸³»¾ú´Ù. ÁÂ, ¿ì ºÐÆ÷¿µ»ó¿¡ ´ëÇÑ Á¤·ùȭó¸® ÈÄ ½ºÅ×·¹¿À ¿µ»ó¿¡ ´ëÇÑ °¡½ÃÈ­°á°ú¸¦ µµÃâÇÏ¿´´Ù.
¿µ¹®³»¿ë
(English Abstract)
In the study, stereo-based of gamma-ray sources detector for the space including the gamma-ray source to scan in a raster scan method, and obtains a visible light image and the gamma-ray image. We went to retrieve and visualize the distance to source and the direction of the 3-dimension information from Stereo gamma-ray detectors. Configuration of the detector consisted of gamma-ray detecting sensor for gamma-ray Sources, pan-tilt for the scanning of the raster for detecting sources, and CCD camera for visible-light image. Implement a stereo structure of the device to measure the spatial distribution of source, the gamma-ray Detector and CCD camera for the stereo image acquisition was as each configuration 2. The gamma-ray detector and a visible light camera to revision the distribution of detection source, After performing each of the cameras of the stereo correction and shows the distribution of the gamma-ray Sources through Áßø visible light image and the gamma-ray image. After Rectification process of Left and right image, we were derived visualization results of the stereo I mage.
Å°¿öµå(Keyword) °¨¸¶¼± ŽÁöÀåÄ¡   ½ºÅ×·¹¿À ¿µ»ó   Ä«¸Þ¶ó º¸Á¤   ½ºÅ×·¹¿À ¹æ»ç¼±¿ø ŽÁö  