ÇѱÛÁ¦¸ñ(Korean Title) I-123 ÇÙÁ¾»ý»êÀåÄ¡ ½Ã½ºÅÛ ¼³°è
¿µ¹®Á¦¸ñ(English Title) Design of I-123 Nuclide production system
ÀúÀÚ(Author) Á¤Çö¿ì   À¯ÀçÁØ   ±èº´ÀÏ   Àü±Ç¼ö   ÀÌÁö¼·   ¹ÚÇö   ÃÖÁØ¿ë   ¿À¼¼¿µ   ¹æ»ó±Ç   À̵¿ÈÆ   Hyun-Woo Jung   Jae-Jun You   Byung Il Kim   KwonSoo Chun   Ji-Seub Lee   Hyun Park   JunYong Choi   Se-Young Oh   Sang-Kwon Bang   Dong Hoon Lee  
¿ø¹®¼ö·Ïó(Citation) VOL 18 NO. 01 PP. 0496 ~ 0499 (2014. 05)
Çѱ۳»¿ë
(Korean Abstract)
30MeV CyclotronÀÇ ¾ç¼ºÀÚ°¡ Xe-124 ±âü Ç¥Àû ½Ã½ºÅÛ¿¡ Á¶»çµÉ ¶§ °¡´ÉÇÑ ÇÙ¹ÝÀÀÀ» Àû¿ëÇÏ¿© Xe Gas¸¦ GPMÀ¸·ÎºÎÅÍ TargetÀ¸·Î ±îÁö Àü¼ÛÇÏ´Â ½Ã½ºÅÛÀ» ¼³°èÇÏ°í Á¦ÀÛÇÏ¿´´Ù. ½Ã½ºÅÛ ¼³°è´Â Å©°Ô 4ÆÄÆ®·Î ³ª´©¾î ¼³°èÇÏ¿´´Ù. °¢°¢ÀÇ Çϵå¿þ¾î ºÎºÐÀº ¼Ö¸®µå¿÷½º¸¦ ÀÌ¿ëÇÏ¿© ¼³°èÇÏ¿´´Ù. TargetÀº Çï·ýÀ¸·Î Havor FoilÀ» Ä𸵽ÃÅ°°Ô ¼³°èÇß°í ¹°Àº Ÿ°Ù¿¡ µé¾î°£ Xe Gas¸¦ Á¶»ç ½Ã ³ô¾ÆÁö´Â ¿Âµµ¸¦ ½ÄÇôÁÖ´Â ¿ªÇÒÀ» ÇÏ°Ô Á¦ÀÛÇÏ¿´°í ¿Âµµ¼¾¼­¿Í ¾Ð·Â¼¾¼­¸¦ ÀåÂøÇÏ¿© ´«À¸·Î È®ÀÎÇÒ ¼ö ÀÖ°Ô Á¦ÀÛÇÏ¿´´Ù. GPM(Gas Process Manifold)Àº Xe Gas¸¦ ¿î¹ÝÇϵµ·Ï ÁغñÇÏ´Â ºÎºÐÀ̸ç Xe Gas¸¦ ´ã°íÀÖ´Â ºÎºÐ°ú ºÒ¼ø¹°À» Á¦°ÅÇÏ´Â ºÎºÐÀÌ ÀÖ´Ù. HCS(Helium Circulation System)Àº Çï·ýÀ» ÀÌ¿ëÇÏ¿© °¢ÆÄÆ®¸¦ Ŭ¸®´× ÇÏ°í ³Ã°¢½ÃÄÑ ÁØ´Ù. ÀÌ·¯ÇÑ °¢ ºÎºÐµéÀ» PLC·Î Á¦¾îÇÏ°Ô ÇÏ¿© À¯Áöº¸¼ö½ÃÀÇ Æí¸®¼ºÀ» Ãß±¸ÇÏ¿´°í PC Vue¸¦ »ç¿ëÇÏ¿© SIEMENS PLC¸¦ ´õ¿í´õ ¾ÈÀüÇÏ°Ô ÀÎÅÍÆäÀ̽ºÇÏ°Ô ÇÏ¿´´Ù.
¿µ¹®³»¿ë
(English Abstract)
Xe Gas is moved to Target from GPM. It is Used to feasible nuclear reaction from proton of 30MeV Cyclotron being investigated by the Xe-124 Gas target System. This system is divided into four parts. Hardware was constructed by solidworks and Helium Supply is to cool the Havor Foil. Water has the job of cooling down the temperature when Xe Gas is being investigated in the target. Temperature and pressure gauges are attached to be checked easily. GPM(Gas Process Manifold) has the part that prepares to transport Xe Gas. There are Storage Vessel that stores Xe Gas, the cold trap that filters humidity and impurity and lastly storage vessel that temporarily stores Xe Gas. HCS(Helium Circulation System) using the Helium to cleaning and cooling. these parts are used to SIEMENS PLC and Pcvue Program. Because It is more comfortable and easy maintenance.
Å°¿öµå(Keyword) I-123   Xe Target   PC Vue   Radiopharmaceuticals   radiation   production system  