Current Result Document :

ÇѱÛÁ¦¸ñ(Korean Title) ÄÄÇ»ÅÍ ´ÜÃþÃÔ¿µ(CT) ¹æ»ç¼± ³ëÃâ °ü¸® ½Ã½ºÅÛ ¼ÒÇÁÆ®¿þ¾î ¼³°è
¿µ¹®Á¦¸ñ(English Title) System Software Design of Computed Tomography Radiation Dose Management
ÀúÀÚ(Author) ¾çÀ¯¹Ì   À̱æÈï   Á¶»ó¿í   Yu-mi Yang   Kil-hung Lee   Sang-wook Cho  
¿ø¹®¼ö·Ïó(Citation) VOL 18 NO. 01 PP. 0489 ~ 0492 (2014. 05)
Çѱ۳»¿ë
(Korean Abstract)
º» ³í¹®¿¡¼­´Â ÄÄÇ»ÅÍ ´ÜÃþÈ°¿µ(CT)À» ÅëÇØ ¹ß»ýµÇ´Â ¹æ»ç¼± ³ëÃâ·®ÀÇ °ü¸®¸¦ À§ÇÑ ½Ã½ºÅÛÀÇ ¼ÒÇÁÆ®¿þ¾î ¼³°è¸¦ Á¦¾ÈÇÑ´Ù. ¹æ»ç¼± ÇÇÆø·®Àº ȯÀÚÀÇ °¢ ½Åü ºÎÀ§º°·Î ¹Î°¨¼ºÀÇ Â÷ÀÌ¿¡ µû¶ó ´Ù¸£±â ¶§¹®¿¡ ¹æ»ç¼±ÀÇ ³ëÃâ·®À» °ü¸®ÇÒ ¼ö ÀÖ°Ô µÇ¸é °á°úÀûÀ¸·Î ȯÀÚÀÇ ¹æ»ç¼± ÇÇÆø·®À» ÃßÁ¤ÇÒ ¼ö ÀÖ´Ù. ÃÖ±Ù ÀϺ» ¿øÀüÀÇ ¹æ»ç¼± ´©Ãâ »ç°ÇÀÌ ±¹Á¦ÀûÀ¸·Î ´º½º°¡ µÇ¾ú°í ¿øÀü »Ó ¸¸¾Æ´Ï¶ó ÀÇ·á¿ë ¹æ»ç¼± ÇÇÆø±îÁö Æø³Ð°Ô °ü½ÉÀÌ Ä¿Áö°í ÀÖ´Ù. ÇöÀç ¹æ»ç¼± ¾ÈÀü°ü¸®´Â ¹æ»ç¼± °ü°è Á¾»çÀÚ¿¡ ´ëÇؼ­¸¸ °ü¸®µÇ°í ÀÖÁö¸¸, ÀÌÁ¦´Â ȯÀÚ¿¡ ´ëÇÑ ÇÇÆø °ü¸®±îÁö ¿ä±¸µÇ°í ÀÖ´Ù. ¿ì¸®³ª¶ó¿¡¼­ ¹æ»ç¼±À» ÀÌ¿ëÇÑ °Ë»ç¿Í ½Ã¼úÀÌ Áõ°¡ÇÏ¿© ÀÌ¿¡ µû¸¥ ÀÇ·á ÇÇÆøÀÌ Áõ°¡ÇÏ¿´À¸³ª ÀÇ·á ±â°ü¿¡¼­´Â ȯÀÚ¿¡°Ô °¡ÇØÁö´Â ¹æ»ç¼± ÇÇÆø ¼öÄ¡¸¦ ¾ËÁö ¸øÇÏ´Â ½ÇÁ¤ÀÌ´Ù. µû¶ó¼­ ÀÇ·á ±â°ü¿¡¼­ ȯÀÚÀÇ ¹æ»ç¼± ÇÇÆøÀ» °ü¸®ÇÒ ¼ö ÀÖ´Â ½Ã½ºÅÛÀÌ ÇÊ¿äÇÏ´Ù. º» ³í¹®¿¡¼­´Â ÀÇ·á ±â°ü¿¡¼­ ¹æ»ç¼±À» ÀÌ¿ëÇÏ´Â ´ëÇ¥ÀûÀÎ ÃÔ¿µ µµ±¸ÀÎ CTÀÇ ¹æ»ç¼± ³ëÃâ·®À» °ü¸®ÇÒ ¼ö ÀÖ´Â ¼ÒÇÁÆ®¿þ¾î ¼³°è¸¦ Á¦½ÃÇÑ´Ù. ¹æ»ç¼±ÀÇ ³ëÃâ·®À» È®ÀÎÇÏ°í ¼±·®ÀÇ Çѵµ¸¦ ¼³Á¤ÇÔÀ¸·Î½á ȯÀÚÀÇ ÀÇ·á ÇÇÆø·®À» ÃÖÀûÈ­ Çϴµ¥ µµ¿òÀÌ µÇ°íÀÚ ÇÑ´Ù.
¿µ¹®³»¿ë
(English Abstract)
This thesis provides the design of system software for the management of radiation dose that is generated using computer tomography(CT). Because radiation exposure is different depending on the difference in sensitivity to each part for each of the patient's body, if we will be able to manage an appropriate amount of radiation, it is possible to estimate the radiation exposure of the patient as a result. Recently, radiation leakage incident of Japanese nuclear power plant was in the news internationally and there is a growing interest not only a nuclear power plant, to medical radiation exposure. In spite of the fact that currently safety management of radiation is under control only the workers of the radiation involved, exposure management of patients until now have been required. Surgery and inspection using the radiation in Korea will increase, due to this medical exposure has increased, but it is a reality that medical institution don't know the level of radiation exposure applied to the patient. Therefore a system for managing the radiation exposure of the patient from the medical institution is required. This paper proposes a design of a software program to manage the radiation exposure of CT is an typical imaging tool to use the radiation in the medical institution. By check the amount of radiation dose and set the limit of dose, we would help to optimize the medical exposure of the patient.
Å°¿öµå(Keyword) ¹æ»ç¼± ³ëÃâ(Radiation Dose)   ¹æ»ç¼± ÇÇÆø °ü¸®(Management of Radiation Exposure)   ÄÄÇ»ÅÍ ´ÜÃþÃÔ¿µ(Computed Tomography)   ÀÇ·á °æ¿µ(Medical Management)   ȯÀÚ ¸¸Á·µµ(Patient Satisfaction)  