ÇѱÛÁ¦¸ñ(Korean Title) ³úµ¿¸Æ·ù ÄÚÀÏ »öÀü¼ú ½Ã Bismuth Â÷Æóü ¼³Ä¡¿¡ µû¸¥ ÀÔ»ç Ç¥¸é ¼±·® Æò°¡ ¹× È­Áú Æò°¡
¿µ¹®Á¦¸ñ(English Title) Evaluation of entrance surface dose and image quality according to the installation of Bismuth shield in the case of endovascular treatment of cerebral aneurysm
ÀúÀÚ(Author) ±èÀç¼®   ±è¿µ±æ   ÃÖÀçÈ£   Jae-Seok Kim   Young-Kil Kim   Jae-Ho Choi  
¿ø¹®¼ö·Ïó(Citation) VOL 23 NO. 07 PP. 0779 ~ 0785 (2019. 07)
Çѱ۳»¿ë
(Korean Abstract)
ÀÎü°øÇÐÀûÀ¸·Î °³¹ßµÈ Bismuth Â÷Æóü¸¦ ³úµ¿¸Æ·ù ÄÚÀÏ »öÀü¼ú¿¡ Àû¿ëÇÔÀ¸·Î½á ÀÇ·á¹æ»ç¼± ÇÇÆøÀ¸·ÎºÎÅÍ µÎÇÇ ¹× ¼öÁ¤Ã¼ÀÇ ¹æ»ç¼± ÇÇÆøÀ» °¨¼Ò½ÃÅ°°íÀÚ ÇÏ¿´´Ù. ±¤ÀÚ±Ø Çü±¤ ¼±·®°è¸¦ ÀÌ¿ëÇÏ¿© ÈĵκÎ, ¾çÂÊ ÃøµÎºÎ, ¾çÂÊ ¼öÁ¤Ã¼ºÎ, ÄÚ ³¡ºÎ¸¦ °³¹ßµÈ Bismuth Â÷Æóü¸¦ »ç¿ë Àü (A±×·ì) ÈÄ (B±×·ì)·Î ÃøÁ¤ÇÏ¿© ÀÔ»ç Ç¥¸é ¼±·®À» ºÐ¼®ÇÏ¿´´Ù. Bismuth Â÷Æóü¸¦ »ç¿ëÇÒ °æ¿ì È­Áú¿¡ ´ëÇÑ Æò°¡¸¦ Signal to noise ratio (SNR)°ú Contrast to noise ratio (CNR) ºÐ¼®À» Çß´Ù. A ±×·ì°ú B ±×·ìÀÇ ÀÔ»ç Ç¥¸é Æò±Õ ¼±·®À» ºñ±³ÇÑ °á°ú A ±×·ì¿¡ ºñÇØ B ±×·ì¿¡¼­ Æò±Õ 26.92% °¨¼ÒµÇ¾ú´Ù. CNR°ú SNRÀÇ ºÐ¼®Àº ·Îµå¸Ê°ú µðÁöÅÐ °¨»êÁ¶¿µ ¸ðµÎ µ¿ÀÏÇÏ°Ô ÃøÁ¤µÇ¾ú´Ù. Bismuth Â÷ÆóüÀÇ »ç¿ëÀº ³úÇ÷°ü ÁßÀçÀû ½Ã¼ú ÈÄ ³ªÅ¸³¯ ¼ö ÀÖ´Â ÀϽÃÀû Å»¸ð ¹× ±âŸ È®·üÀû ¿µÇâ¿¡ µû¸¥ ¹æ»ç¼± Àå¾Ö¸¦ È­ÁúÀÇ ÀúÇÏ ¾øÀÌ °¨¼Ò½Ãų ¼ö ÀÖ´Â ´ë¾ÈÀÌ µÉ °ÍÀ¸·Î »ç·áµÈ´Ù.
¿µ¹®³»¿ë
(English Abstract)
By applying an ergonomically developed Bismuth shield to the endovascular treatment of cerebral aneurysm the radiation dose of the scalp and lens from the medical radiation exposure was reduced. The enrtance surface dose was analyzed by measuring the occipital parts, bilateral temporal parts, bilateral quadriceps, and nasal tip of the developed bismuth shield using a photostimulable fluorescence dosimeter before (Group A) before use (Group B). Signal to noise ratio (SNR) and contrast to noise ratio (CNR) analysis were used to evaluate the image quality when Bismuth shielding was used. The mean entrance surface dose of A group and B group was 26.92% lower than that of A group. The analysis of CNR and SNR was the same for both Roadmap and DSA. The use of Bismuth shielding is an alternative that can reduce the radiation impairment due to temporary hair loss and other stochastic effects that may occur after cerebrovascular intervention.
Å°¿öµå(Keyword) ³úÇ÷°ü ÁßÀçÀû ½Ã¼ú   Bismuth Â÷Æóü   ¹æ»ç¼± ÇÇÆø   ¹æ»ç¼± ¹æ¾î   Cerebrovascular intervention   Bismuth shield   Radiation exposure   Radiation protection  